What Are Air Duct Cleaning Engineering Controls?

Engineering controls are techniques used to ensure the safety of the health of the building’s occupants and air filters cleaning that there is no cross-contamination in HVAC system maintenance and cleaning processes. These methods include:

  • Control of the source and zone off
  • Isolation barriers/Containment
  • Pressure differential
  • Dust suppression
  • HEPA vacuuming and filters
  • Complete cleaning
  • Control of humidity and temperature

 

These controls in engineering affect the many aspects of air cleaning of ducts. You may not be thinking of. These comprise:

 

  • Maintenance of equipment All equipment must be in good condition and in good working in good working.
  • Before starting the project Clean and inspect the equipment to ensure that no contaminants are introduced.
  • During the course of the project Maintain/service the equipment in order to prevent the risk of cross-contamination.
  • Maintenance of filters throughout the construction: If the vacuum collection equipment on-site needs to be opened for service or change of filters, it should be done in a contained space or outside the building.
  • Equipment transportation/relocation: all equipment shall be clean and sealed before relocating or removing from building.
  • On-site verification of equipment It is recommended that maintenance verification on site be conducted on vacuum collection equipment prior to use.
  • Equipment powered by fuel should be placed to block emissions from entering the building.
  • Vacuum exhausting equipment for indoor use should use HEPA filtering with 99.97 percent efficiency of collection to 0.3 micron particles.
  • Negative pressure conditions Continuous negative pressure must be maintained within the area that is that is being cleaned, in relation to the space that surrounds it.
  • Handling of materials that are contaminated All materials that are contaminated should be appropriately contained before being removed from the construction.
  • Air cleaning in the ambient It is recommended that the cleaning of air with HEPA air scrubbers that are filtered be utilized during and following HVAC cleaning and restoration in order to ensure at least four air changes every hour.
  • Control of the emission of products Follow the manufacturer’s application guidelines, which includes exhaust ventilation for chemical cleaners and other cleaning agents.
  • Positive pressure loss It is suggested that backup equipment be available with a separate power source to avoid negative pressure loss because of malfunctioning equipment or power disruption.

 

The four different levels of containment you can be used to stop cross-contamination

Niveau 1 is the minimum level employed in every project.

 

  • Negative pressure
  • Coverings for protection
  • Cleaning equipment and tools
  • Cross-contamination control

 

Level 2: include Level 1, plus temporary hrv cleaning barriers.

 

  • Temporary barriers to containment
  • Containment of floor area
  • Validate negative pressurization
  • Ambient air cleaning
  • Deconstruction

 

Level 3: includes Level 1 & 2, plus a single decontamination chamber.

 

  • Decontamination facility
  • Requirements for monitoring

 

Level 4: includes Level 1, 2 & 3, plus two decontamination chambers.

 

  • Decontamination facility
  • Requirements for monitoring

 

A proper engineering control system should be employed on every HVAC restoration and cleaning project. The safety of workers, building occupants and avoiding cross contamination must be the top priority.